Insulating a loft, attic or stud wall? This calculator works out the area of insulation you need, allowing for more than one layer, and turns it into a number of rolls or packs once you enter the coverage printed on the pack.
How to use it
- Measure the length and width of the loft floor or wall area.
- Choose the number of layers. A common approach for lofts is one layer between the joists and a second layer laid across them.
- For a layer fitted between joists or studs, you can deduct the area taken up by the timber (often around 10%).
- Enter the coverage per pack from the label for the thickness you are buying.
Worked example
An 8 × 6 m loft is 48 m². Two layers need 96 m² of insulation (slightly less if you deduct the joists from the first layer). If a pack covers 5.61 m² at your chosen thickness, 96 × 1.05 ÷ 5.61 = 18 packs.
How thick should insulation be?
Recommended thickness, or the R-value / U-value it must achieve, depends on where you live and the part of the building. In the UK, guidance for lofts is commonly expressed as a total depth of mineral wool; in the US and Australia it is usually given as an R-value for your climate zone. Check current local building regulations or energy-efficiency guidance before you buy.
Safety
- Wear gloves, long sleeves and a dust mask when handling mineral wool.
- Keep insulation clear of recessed light fittings and flues unless the product and fitting are rated for contact.
- Do not block eaves ventilation; the loft must stay ventilated to avoid condensation.
- Lay boards on the joists to walk on; never step between the joists.
Estimates only. Required thickness and fire-safety details depend on local regulations and the product.